HOW DO YOU TEST YOUR PFD USING THE AUTOMATIC
INFLATOR?

The U.S.Coast Guard recommends that you purchase at least one spare
re-arming kit (MA7218).

1) To test your Inflatable Vest with LIFT

TM

, you will need your fully

armed Inflatable Vest with LIFT

TM

, and re-arming kit (MA7218)

approved for your Inflatable Vest with LIFT

TM.

2) Put on the Inflatable Vest with LIFT

TM

.

3) Get into shallow water, just deep enough that you can stand with

your head above the surface. Once the inflator is underwater, 4
inches or so, the Inflatable Vest with LIFT

TM

should fully inflate

automatically within 5 seconds.

4) See if the Inflatable Vest with LIFT

TM

will float you on your back or

just slightly back of vertical. In a relaxed floating position, verify
that your mouth is well above the water’s surface. Note the effect of
where you hold your legs on how you float.

5) Get out of the water and remove the Inflatable Vest with LIFT

TM

.

6) Deflate the Inflatable Vest with LIFT

TM

by depressing the oral inflator

valve (see Deflation p. 11). Remove the used inflator.

7) Let the Inflatable Vest with LIFT

TM

dry thoroughly. Re-arm (p. 13) and

Repack the PFD (p. 17).

HOW DO YOU TEST YOUR PFD USING THE MANUAL
INFLATOR?

The U.S.Coast Guard recommends that you purchase at least one spare
re-arming kit (MA7218).

1) To test your Inflatable Vest with LIFT

TM

, you will need your fully

armed Inflatable Vest with LIFT

TM

, and re-arming kit approved for

your Inflatable Vest with LIFT

TM

: MA7218.

31