Section 3 − definitions, Section 4 − specifications, 1. weld, power, and engine specifications – Miller Electric BLUE STAR 145 DX User Manual

Page 13: 1. symbol definitions

Advertising
background image

OM-4417 Page 9

SECTION 3 − DEFINITIONS

3-1. Symbol Definitions

Engine Choke

Read Operator’s

Manual

A

Amperes

V

Volts

Engine Oil

Fuel

Battery (Engine)

Engine

Positive

Negative

Alternating Current

(AC)

Output

h

Hours

s

Seconds

Time

Protective Earth

(Ground)

Circuit Protector

Temperature

SECTION 4 − SPECIFICATIONS

4-1. Weld, Power, And Engine Specifications

Welding

Mode

Weld

Output

Range

Rated

Welding Output

Maximum

Open Circuit

Voltage

Generator

Power Rating

Fuel

Capacity

Engine

CC/DC

40 − 145 A

145 A, 25 V,

20% Duty Cycle

100 A, 25 V,

60% Duty Cycle

80 A, 25 V

100% Duty Cycle

80

Single-Phase,

4.5 kVA/kW (Peak)

4 kVA/kW

(Continuous)

34/17 A,

120/240 V AC,

60 Hz

Standard Model:

1.8 gal (6.9 L)

Tank

DX Model:

5 gal (19 L)

Tank

Kohler CS10

Air-Cooled,

One-Cylinder,

Four-Cycle,

10 HP (300 CC),

Gasoline Engine

(Recoil Or Electric-

Start)

Advertising