5. duty cycle, 6. generator power curve – Miller Electric BLUE STAR 145 DX User Manual

Page 16

Advertising
background image

OM-4417 Page 12

Continuous Welding

4-5. Duty Cycle

220 625−A

Duty cycle is the percentage of 10

minutes that unit can weld at rated

load without overheating.
Y Exceeding duty cycle can

damage unit and void

warranty.

100% Duty Cycle at 80 Amperes CC/DC

20% Duty Cycle at 145 Amperes CC/DC

% DUTY CYCLE

WELD AMPERES

0

0

10

20

20

30

40

40

50

60

60

70

80

80

90

100

100

120

140

160

2 Minutes Welding

8 Minutes Resting

4-6. Generator Power Curve

220 581

The ac generator power curves

show the generator power available

in amperes at the receptacles.

AMPERES

0

0

10

20

30

40

50

60

70

80

50

100

150

200

250

300

240 Volt

120 Volt

VOL

TS

Advertising