Section 5 − installation, 1. installing welding generator, 2. grounding generator to truck or trailer frame – Miller Electric BLUE STAR 145 DX User Manual

Page 17

Advertising
background image

OM-4417 Page 13

SECTION 5 − INSTALLATION

5-1. Installing Welding Generator

Ref 151 556 / Ref. 800 652 / 803 594-B / S-0854

18 in

(460 mm)

18 in

(460 mm)

18 in

(460 mm)

18 in

(460 mm)

18 in

(460 mm)

OR

Movement

Airflow Clearance

Location

Shown with

optional

running gear.

Y Always securely fasten welding generator

onto transport vehicle or trailer and comply

with all DOT and other applicable codes.

5-2. Grounding Generator To Truck Or Trailer Frame

install1 11/02* − Ref. 151 556 / S-0854

Y Always ground generator

frame to vehicle frame to pre-

vent electric shock and static

electricity hazards.

1

Metal Vehicle Frame

2

Equipment Grounding

Terminal

3

Grounding Cable

Use #10 AWG or larger insulated

copper wire.
Y If unit does not have GFCI

receptacles, use GFCI-

protected extension cord.

Electrically bond generator frame

to vehicle frame by metal-to-metal

contact.

GND/PE

2

3

1

Y Bed liners, shipping skids, and some running

gear insulate the welding generator from the ve-

hicle frame. Always connect a ground wire from

the generator equipment grounding terminal to

bare metal on the vehicle frame as shown.

Advertising