2. dimensions, weights, and operating angles, 3. volt-ampere curves – Miller Electric BLUE STAR 145 DX User Manual

Page 14

Advertising
background image

OM-4417 Page 10

4-2. Dimensions, Weights, And Operating Angles

Dimensions

Height

22-3/4 in (578 mm)

D

Width

22-3/4 in (577 mm)

D

Depth

31-5/8 in (803 mm)

Y Do not exceed tilt angles or engine could

A

31-5/8 in (803 mm)

B

Y Do not exceed tilt angles or engine could

be damaged or unit could tip.

B

10-9/16 in (268 mm)

Y Do not move or operate unit where it

could tip

C

13-25/64 in (340 mm)

could tip.

D

22-3/4 in (577 mm)

A

E

1-9/16 in (40 mm)

A

C

F

19-5/8 in (498 mm)

C

G

13/32 in (10 mm) Dia.

Weight

G

15

°

15

°

DX Model: 309 lb (140 kg)

4

H l

G

15

°

15

°

Standard Model: 263 lb (119 kg)

Holes

15

F

Optional Lifting Eye

Weight Rating

803 403

Engine End

F

E

803 594-B

430 lb (195 kg)

4-3. Volt-Ampere Curves

220 602

The volt-ampere curve shows the

minimum and maximum voltage

and amperage output capabilities of

the welding generator. Curves of all

other settings fall between the

curves shown.

AMPERES

VOL

TS

0

0

50

100

150

200

250

50

20

10

30

40

60

70

80

90

MIN

MID

MAX