SECTION 4 − INSTALLATION

4-1. Specifications

Model

Rated

Welding

Amp

Range DC

Maximum

Open-

Circuit

IP

Rating

Amperes Input at Rated Load Output, 50 or 60 Hz,

Three-Phase

Model

Welding

Output

Range DC

Circuit

Voltage DC

Rating

200 V

230 V

380 V

400 V

440 V

460 V

575 V

KVA

KW

300

Amp

300 A @

32 Volts

DC, 60%

Duty Cycle

15 − 395

68

(70)

21M

70

4.0*

61

3.6*

35

1.1*

33

1.1*

31

1.0*

31

3.1*

25

1.5*

24.5

1.3*

13.8

0.67*

450

Amp

450 A @

38 Volts

DC, 60%

Duty Cycle

20 − 590

71

(70)

21M

102

3.5*

89

3.1*

54

1.5*

51

1.4*

47

1.2*

45

1.5*

36

1.2*

35.5

1.2*

23.3

0.51*

650

Amp

650 A @

44 Volts

DC, 60%

Duty Cycle

50 − 850

71

(70)

21M

−−

124

5.2*

75

1.7*

71

1.6*

65

1.5*

62

2.6*

50

2.1*

49.4

2.1*

36

0.58*

*While idling

( ) Indicates specification differences for CE models

4-2. Duty Cycle And Overheating

6 Minutes Welding

4 Minutes Resting

Duty Cycle is percentage of 10 min-

utes that unit can weld at rated load

without overheating.
If unit overheats, thermostat(s)

opens, output stops, and cooling

fan runs. Wait fifteen minutes for

unit to cool. Reduce amperage or

duty cycle before welding.
Y Exceeding duty cycle can

damage unit and void

warranty.

Overheating

0

15

A

OR

Reduce Duty Cycle

Minutes

duty1 4/95 / Ref. SA-168 919

Example: 60% Duty Cycle =