Maytag WINSLOW PI40 User Manual

Page 11

Advertising
background image

11

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

Cap

Flashing

Outside Air Pipe

Listed Pellet Pipe or

Flex Liner

Storm Collar

Figure 12

CONTROL BOARD

36" FIREPLACE OPENING

18"

13-1/2"

FIREPLACE OPENING C/L

19-1/4"

18-3/8"

HEARTH / FLOOR PROTECTION

31-3/4"

11"

7-7/16"

6-11/16"

138°

41" SURROUND WIDTH

2-15/16"

Figure 11B

Mobile Home Installations

The following steps are required for installation of the Winslow™

PI40 insert in mobile homes. See Figure 12.

1. Connecting the Winslow PI40 insert to outside combustion

air is optional, except in mobile home installations and when

required by local building codes. The insert’s air intake will

accept 2” ID pipe to accommodate outside air installations.

The air intake on the exterior of the home should always

be located substantially below the flue termination and

terminate with a cover to keep out weather and pests.

2. The insert must be fastened to the hearth/floor using lag

screws. The screws can be inserted through the holes in

the base located behind the side doors. If the hearth is

concrete or masonry, use proper lag bolts and methods

designed for anchoring to masonry or concrete.

3. The insert must be grounded with a #8 or larger copper

wire.

WARNING: DO NOT INSTALL THIS INSERT IN A SLEEP-

ING ROOM IN A MANUFACTURED HOME.

CAUTION: THE STRUCTURAL INTEGRITY OF THE

MANUFACTURED HOME FLOOR, WALL, AND CEIL-

ING/ROOF MUST BE MAINTAINED.

CONTROL

BOARD

18"

13-1/2"

FIREPLACE OPENING C/L

21-1/2"

18-3/8"

HEARTH/FLOOR PROTECTION

31-3/4"

11"

7-7/16"

6-11/16"

138°

3"

41" SURROUND WIDTH

32" FIREPLACE OPENING

DEEP

SURROUND

Figure 11C

Fireplace Installation Using Standard Surround Kits

(P/N 79004, 79005, 79006 and 79007)

Fireplace Installation Using 3 Inch Deep ZC Surround Kit

(P/N 7903 *)

* This black surround kit positions the insert 3” forward so that it will allow the insert to fit

into a fireplace with a narrower width in the front (32” min.). Note: No trim kits are avail-

able for this kit at this time. See instruction sheet P/N 506033-05 for more information.

Termination Cap