NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

Mantel

Floor Protection

Combustible

Wall

6”

(15mm)

9-1/”

(41mm)

7-1/”

(191mm)

10”

(54mm)

Max.

6”

(15mm)

3-3/8”

(594mm)

3”

(76mm)

1-1/”

(38mm)

The floor protector must be a non-combustible material extending

beneath the insert from the surround panels forward and to the front

and sides as shown in Figure 7. Important, if anything other than a

masonry hearth is used in the installation you must use the Heat Kit

(Cat. No. 7904).

Minimum Size Floor Protection

Outline of Insert Base

Zero Clearance Kit and Heat Kit Installation

The Winslow™ PI40 insert has a Zero Clearance Kit (Cat. No. 79025) and

a Heat Kit (Cat. No. 79024) approved for new construction or remodel

installations. See Zero Clearance and Heat kit installation instructions at

the back of this manual for requirements. Both kits have been tested and

approved through OMNI Testing Laboratories Inc.

6”

(15mm)

6”

(15mm)

3”

(76mm)

3”

(76mm)

6”

(15mm)

Insert Base

Firebox Front Edge

Floor Protection

31-3/4”

(807mm)

7-7/16”

(189mm)

19-1/4”

(489mm)

6-11/16”

(170mm)

6-11/16”

(170mm)

18-3/8”

(467mm)

Hearth Protection

(shaded gray)

Figure 6

Figure 7

Figure 8

CLEARANCES TO COMBUSTIBLES

INSTALL VENT AT CLEARANCES SPECIFIED BY THE VENT

MANUFACTURER.

Important: The control board attaches to the back of the right

side surround panel. Therefore, the width of the fireplace firebox

needs to be 36” (914 mm) wide at the front if the insert with control

board is to slide into the firebox. Extended surround panels are

available to accommodate narrower fireboxes.

IMPORTANT

• Minimum clearances specified may not allow

for ease of operation and maintenance (please

take this in to account when planning the instal-

lation).

• Recommended clearance zone from the front

of the appliance to combustibles is 4 feet mini-

mum.

• Clearances to combustibles for the appliance

can only be reduced by means approved by the

regulatory authority.

HEARTH PROTECTION