NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

Heat Kit Instructions

Kit Contents

(Refer to Figure 47)

1 ea. 2” lower trim piece (A)

1 ea. 1” insulated micro board (B)

2 ea. 1/2” x 10-24” screws (C)

Tools Required

5/32 allen wrench

1. Install the 2” lower trim piece. Fasten the 2” trim piece underneath

the base of the front of the insert using the 2 screws (see C in Figure

47) provided, one at the left side and one at the right side base of the

insert. Note: This process will be simplified by very cautiously tilting

the insert back (see Figure 48).

2. Install your 4 leveling bolts. Open the main front door and remove the

2 bolts in the front right and front left of the bottom of the fire box see

Figure 49. Note: Placing a level on the insert top is recommended to

ensure your insert is level. Again with the insert very cautiously tilted

back insert your 4 leveling bolts approximately 2-1/16” (52 mm) into

the holes provided at the bottom of the insert (see Figure 50).

3. Set insert on micro board. Now that the insert is level, place your micro

board in place where the insert will be installed and set the Winslow

PI40 insert over the micro board so the 2 front leveling legs line up

with the two cut-outs in the front of the micro board see Figure 51.

Your Winslow PI40 insert heat kit is now installed.