9. process set up push button, Section 6-9 – Miller Electric OM-220 390F User Manual

Page 27

Advertising
background image

OM-220 390 Page 23

6-9. Process Set Up Push Button

Press the Process Set Up push button the

first time will illuminate the button LED and

the Process LED. The upper and lower

displays will be used for Accu-pulse and

only the lower display for MIG, Pulse and

RMD (optional) to show the current process

installed in this program. To change

process, turn the adjust knob.

Pressing the Process Set Up push button a

second time will illuminate the Wire Type

LED and the lower display will show wire

types available for selected processes (see

Table 4-1 for wire abbreviation). To make a

selection, turn the Adjust knob.

Pressing the Process Set Up push button a

third time will keep Wire Type LED lit and the

upper display will show wire alloy type (see

Table 4-1 for alloy types). The upper display

push-button LED will be flashing indicating

that turning the Adjust knob will change the

alloy type for the selected process and wire

type.

Pressing the Process Set Up push button a

fourth time will keep Wire Type LED lit and

the upper display will show wire size. The

upper display push button will be flashing

indicating that turning the Adjust knob will

select wire sizes available for that particular

process and wire type.

Pressing the Process Set Up push button a

fifth time will illuminate the Gas Type LED

and the lower display will show GAS and the

upper display will show gas selection (see

Table 4-1 for gas abbreviations). To make a

gas type selection, turn the Adjust knob.

If any of the Process, wire type, alloy type,

wire size, or gas type was changed, then

pressing the Process Set Up push button a

sixth time will show PROG in the upper

display and LOAD in the lower display. The

new program would be loaded for that

particular program in slot 1 thru 8. If no

changes were made to any setup items, no

program will be loaded, and unit will return

to standby mode.

If a custom program is loaded using an

optional PDA with File Management

software, the Program Display will have a

“C” in front of the program number. This

indicates that the program is not a factory

default program and has been modified. By

selecting or changing any process variable

and performing a program load will restore

the program back to the factory default

program.

Pressing and holding the Process Set Up

push button in on power up allows viewing

the software revisions of each circuit board

in the system. The top display shows the

board (PCM, UIM, WFCM, and AIM

(automated units only) and the lower display

shows the last 3 digits of the circuit board

part number plus a letter designator. Press

the flashing Feeder Set Up push button to

exit the screen displays and continue the

power up process.

3

1

Process Set Up Push Button

2

Process Set Up LED

3

Program Selection LEDs

Process Setup

1

2

Table 4-1. Welding Wire And Gas Abbreviations*

Wire Description

Wire Abbreviation

Alloy Type

Gas Type

Gas Abbreviation

Steel

STL

E70, E100, E120

100% CO

2

,

90% Argon/10% CO

2

,

85% Argon/15% CO

2

,

75% Argon/25% CO

2

,

95% Argon/5% CO

2

,

95% Argon /5% O

2

,

98% Argon/2% O

2

CO2

C10

C15

C25

C5

OX5

OX2

Stainless Steel

SS

308, 309, 312, 316

98% Argon, 2% O

2

(81Ar/18HE/1CO

2

Accu-pulse)

90HE/7-1/2Ar/2-1/2CO

2

MIG/RMD/Accu-pulse)

OX2

Tri Gas

Tri Gas

Cored Tubular Wire

MCOR

71, 76, 86R, 409,

439

90% Argon/10% CO

2

C10

439

98% Argon/2% O

2

OX2

Aluminum

ALUM

4XXX, 5XXX

100% Argon

ARGN

* Not all wire types may be available with your unit.

Advertising