6-11. Reset Mode

198 993 / 803 504-B

.

Reset mode is not active when
Program Lock is enabled.

The reset mode allows the operator to

reload factory program settings for all

eight active programs in the unit.

.

System configuration data will be
lost during the Reset operation.

Enter reset mode by turning power On and pressing

the Program Push Button until the RST NO message

is displayed. RST NO message will not display until

after the power-up sequence is completed

(approximately 20 seconds).

Rotate Adjust knob to change NO

to YES.

Program 1

Pulse

.035 Mild Steel

90% Argon, 10% CO

2

Program 2

MIG

.035 Mild Steel

75% Argon, 25% CO

2

Program 3

Accu-pulse

.035 Mild Steel

90% Argon, 10% O2

Program 4

Pulse

.045 Mild Steel

90% Argon, 10% CO

2

Program 5

MIG

.045 Mild Steel

75% Argon, 25% CO

2

Program 6

Accu-pulse

.045 Mild Steel

90% Argon, 10% O2

Program 7

Pulse

.052 Mild Steel

90% Argon, 10% CO

2

Program 8

MIG

.052 Mild Steel

75% Argon, 25% CO

2

Press the Arc Control button to

confirm the reset.

The reset message is displayed for

2 seconds while factory program

settings are being reloaded.

During the reset mode the following

factory default programs are loaded

into the unit:

Cycl Pwr message appears on the display

when programs complete loading.

Turn power off, wait 10 seconds, and turn

power back on again to complete the reset

operation.

.

After Reset is complete, be sure to load
appropriate programs that contain the

correct wire size, process, and shielding gas

for the welding operation

Setup

Adjust

Arc Control

V

A

A

RST

NO

Setup

Adjust

Arc Control

V

A

A

RST

YES

Setup

Adjust

Arc Control

V

A

A

RST

YES

Setup

Adjust

Arc Control

V

A

A

CYCL

PWR