OM-220 390 Page 24

6-10. Jog/Purge

The Jog/Purge switch provides the following

functions:

Pressing left side of the Jog/Purge switch

allows the operator to feed wire without

energizing the weld power or gas valve

circuit. The wire will feed at a 50 ipm rate for

3 seconds, then the rate ramps up to 700

ipm until the Jog switch is released.

The unit also provides the ability to jog the

wire feeder by means of the gun trigger.

When the gun trigger is pressed without

starting an arc, the wire will feed at run-in

speed for the first 3 seconds. During this

time OCV (open circuit voltage) will be

present as indicated on feeder upper

display. After 3 seconds the weld output

turns off and the wire will feed at 50 ipm for

the next 3 seconds and then ramps up to

700 ipm until trigger is released or 30

seconds elapses. If the gun trigger is still

activated after 30 seconds, the jog

operation is terminated to prevent complete

unspooling of the wire and an “ERR STRT”

message is displayed on the upper and

lower displays. Releasing and pressing the

trigger again will clear the error.

.

If Start Error is enabled using an optional
PDA with File Management software, an

“ERR STRT” will occur after the first 3

seconds of run in and jogging from the

trigger is not possible.

Pressing right side of the Jog/Purge switch

allows the operator to purge gas lines before

welding and to preset gas pressure at the

regulator.

This unit is equipped with Auto Thread

capability. By rocking the switch from purge

to jog within 0.5 seconds will automatically

feed wire for a factory default setting of 192

in (4877 mm) of wire before stopping. The

default feed rate is 700 ipm. These settings

can be changed using an optional PDA with

File Management software. Pressing the

Jog/Purge switch or gun trigger during Auto

Threading will terminate the automatic feed

operation.

1

803 505-A

2

3

1

Jog/Purge Push Button

2

Adjust Knob

3

Gun Trigger Receptacle

Advertising