OM-216 244 Page 9

SECTION 3 − INTRODUCTION

3-1. Specifications

Amperage

Range in

Max. Open-

Circuit

RMS Amps Input at Rated Load

Output, 60 Hz 3-Phase at NEMA

Load Voltages and Class I Rating

Rated Welding Output

Range in

CC Mode

Circuit

Voltage

480 V

575 V

KVA

KW

1000 A at 36 VDC,

3-Phase

27% Duty Cycle

50−1000A

70 VDC

55

(0.10*)

45

(0.08*)

46

(0.09*)

42

(0.04*)

*While idling
**See Section 4-2 for additional information.

.75 second Welding

3.00 seconds Resting

3-2. Duty Cycle And Overheating

Y Exceeding duty cycle can

damage unit and void

warranty.

Percent duty cycle = 1.7 times the

number of 1 second (1000ms)

loads/outputs per minute, without

overheating. The one second load

is the rated output.
If unit overheats, output stops. A

HLP 3 message (see Section 8-4)

is displayed, and cooling fan runs.

Wait fifteen minutes for unit to cool.

Reduce amperage or duty cycle be-

fore welding.

27% Duty Cycle

Overheating

0

15

A or V

OR

Reduce Duty Cycle

Minutes

sduty1 5/95 / SA-207 877

NUMBER OF STUDS IN ONE MINUTE

16

STUD SIZE

0.000

0.125

0.250

0.375

0.500

0.625

0.750

30

40

60