3. foot and leg setup – Miller Electric 625 User Manual

Page 20

Advertising
background image

OM-216 244 Page 16

Foot Installation
1

Leg Screw

2

Leg Washer

3

Ferrule Grip

4

Foot

5

Leg

The foot is available in 3 different sizes

(small, medium, and large) and 2 different

configurations (closed and split). Typically, a

split foot is only used when welding headed

anchors and sheer connectors.

The foot is installed on the ends of the legs.

Unscrew the flat head screws from the ends

of the legs. Place the trim washers on the flat

head screws and place the screws through

the adjustment slots in the foot. Reattach the

screws to the legs.
Leg Installation
6

Flat Side of Leg

7

Leg Set Screw

Insert legs into leg retainers. Line up the flat

side of the legs with set screws Tighten set

screws securely.

4

5-3. Foot and Leg Setup

5

1

2

3

Foot Size

Stud Range

Small

Medium

Up to 1/2 in.

5/8 to 3/4 in.

6

7

Make sure flat side of legs face

outside ot gun body to ensure

alignment with set screws.

Part #

219670

219671

1

Ferrule Grip

There are 3 set screws that retain the ferrule

grip or spark shield in the foot. Loosen all 3

set screws.

Push the ferrule grip or spark shield into the
foot. Press ferrule grip firmly into the foot so
it seats against the back stop. Line up the 2

side holes in the ferrule grip with set screws

in the foot. Tighten set screws securely.

.

If a spark shield is being used, it is not
necessary to align the spark shield with

the set screws in the the foot.

5-4. Ferrule Grip / Spark Shield Removal and Installation

1