Electrical service guide, 7. electrical service guide – Miller Electric OM-229 038D User Manual

Page 15

Advertising
background image

OM-229 038 Page 11

3-7.

Electrical Service Guide

Migmatic Model

221

253

Input Voltage

220/230

230

400

Input Amperes at Rated Output

26

23

13

Max Recommended Standard Fuse or Circuit Breaker Rating in Amperes

26

23

13

** Input Conductor Size in mm

2

4

4

4

** Grounding Conductor Size in mm

2

4

4

4

** Power cord supplied with the unit is sized for 230V operation. Larger power cord may be required for cable lengths greater than 3 meters.

Consult national and local regulations.

3-8.

Selecting a Location and Connecting Input Power (1-Phase and 3-Phase)

A. 1-Phase

803 766-B

Y

Installation must meet all National
and Local Codes − have only quali-
fied persons make this installation.

Y

Disconnect and lockout/tagout in-
put power before connecting input
conductors from unit.

Y

Always connect green or green/
yellow conductor to supply
grounding terminal first, and never
to a line terminal.

1

Black And White Input Conductor
(L1 And L2)

2

Green Or Green/Yellow Grounding
Conductor

3

Input Power Cord.

4

Disconnect Device (switch shown in
the OFF position)

5

Disconnect Device Grounding
Terminal

6

Disconnect Device Line Terminals

Connect green or green/yellow grounding
conductor to disconnect device grounding
terminal first.

Connect input conductors L1 and L2 to
disconnect device line terminals.

7

Over-Current Protection

Select type and size of over-current
protection using Section 3-7 (fused dis-
connect switch shown).

Close and secure door on disconnect
device. Remove lockout/tagout device,
and place switch in the On position.

4

3

L1

L2

1

=GND/PE

Earth Ground

2

1

5

6

7

Tools Needed:

18 in (457 mm)

for airflow

Advertising