B. 3-Phase

803 766-A

Y

Installation must meet all National
and Local Codes − have only quali-
fied persons make this installation.

Y

Disconnect and lockout/tagout in-
put power before connecting input
conductors from unit.

Y

Always connect green or green/
yellow conductor to supply
grounding terminal first, and never
to a line terminal.

For Three-Phase Operation

1

Input Power Cord.

2

Disconnect Device (switch shown in
the OFF position)

3

Green Or Green/Yellow Grounding
Conductor

4

Disconnect Device Grounding
Terminal

5

Input Conductors (L1, L2 And L3)

6

Disconnect Device Line Terminals

Connect green or green/yellow grounding
conductor to disconnect device grounding
terminal first.

Connect input conductors L1, L2, and L3
to disconnect device line terminals.

7

Over-Current Protection

Select type and size of over-current
protection using Section 3-7 (fused dis-
connect switch shown).

Close and secure door on disconnect
device. Remove lockout/tagout device,
and place switch in the On position.

= GND/PE
Earth Ground

L1

2

1

L2

L3

3

3

4

5

6

7

Tools Needed: