MultiModemISDN User Guide

MTA128ST-USB

S-Register: S0
Function:

Number of Rings Until Answer

Unit:

1 ring

Range:

0–255

Default:

1

Description: Sets the number of rings the TA waits for before it answers and begins its

connect sequence. S0=0 turns off the ability to automatically answer a call.
S0=1 causes the TA to automatically answer after 1 ring. If the S0 value is
set too high, the calling device may time out before the TA answers the call.
For autoanswer, S0 must have a nonzero value, DTR must be high (&D
command), and the TA must be offline.

S-Register: S1
Function:

Ring Count

Unit:

1 ring

Range:

0–255

Default:

0

Description: Counts the number of rings that have occurred, up to a maximum of 255. It is

a read-only register and is seldom used in typical operation. If you set S1 to
a value other than its default value of zero or if the value is increasing with
rings, this new value remains stored in S1 for eight seconds after the last
ring is counted, after which time the value reverts to zero.

S-Register: S2
Function:

Escape Character

Unit:

Decimal ASCII code

Range:

0–127

Default:

43 (+)

Description: Specifies the character used by the TA to escape from data mode and return

to command mode.

S-Register: S3
Function:

Carriage Return Character

Unit:

Decimal ASCII code

Range:

0–127

Default:

13 (^M)

Description: Specifies the character used by the TA to indicate the end of a command

line.

S-Register: S4
Function:

Line Feed Character

Unit:

Decimal ASCII code

Range:

0–127

Default:

10 (^J)

Description: Specifies the character used by the TA to indicate the end of a status

message.

S-Register: S5
Function:

Backspace Character

Unit:

Decimal ASCII code

Range:

0–32, 127

Default:

8 (^H)

Description: Specifies the character used by the TA to delete the previous character in the

command line.