Chapter 4 - AT Commands, S-Registers and Result Codes

MTA128ST-USB

S-Register: S53
Function:

Maximum X.75 Buffer Size

Unit:

1 byte

Range:

n=64 - 2048

Default:

2048 (bytes)

Description: S53 allows the maximum buffer size of an X.75 frame to be customized.

Typically a smaller frame size is more compatible with software packages on
a PC (such as HyperTerminal). Larger frame sizes introduce larger delay
which some software cannot deal with appropriately.

S-register: S54
Function:

Force 56 Kbps B-Channel Data Rate

Unit:

Decimal ASCII code

Range:

n=56 (Kbps) or 64 (Kbps)

Default:

64 (Kbps)

Description: S54 can be used to force a 56 Kbps B-channel data rate in order to make 56

Kbps data calls.

S-Register: S55
Function:

POTS Port Call Control

Unit:

Decimal ASCII code

Range:

1, 2, 17, 18

Default:

1

Description: Allows you to set the type of information transfer capability for calls placed

from the POTS port either by a telephone, modem, or fax. Some Central
Office (CO) switches keep track of the type of line each customer has, and if
that line is labeled as a data line (modem or fax), it will not accept a speech
call originated on that line. However, 3.1 kHz audio information transfer
capability is allowed on data lines (modem or fax) by most switches. S55
also lets you define whether a progress indicator information element (which
indicates that the origination address of the POTS call is non-ISDN) is sent
with the SETUP message for the POTS port call. This may help POTS port
calls get through certain CO switches.
S1

Speech, no progress indicator

S2

3.1 kHz Audio, no progress indicator

S17

Speech, origination address is non-ISDN

S18

3.1 kHz Audio, origination address is non-ISDN

S-register: S56 (applies to NET3 [!C0=2] switch type only)
Function:

Calling Party Number IE Settings

Unit:

decimal ASCII code

Range:

128

Disable

Type of Number
0

Unknown,

16

International

32

National

48

Network specific

64

Subscriber

96

Abbreviated

Numbering Plan
0

Unknown

1

ISDN/telephony

3

Data

Advertising