Table II

Maximum effective
duct length allowable

Internal duct di-
ameter required

10 m

with Ring adapter

20 m

without Ring adapter

40 m

without Ring adapter

100 m

without Ring adapter

100 mm
100 mm
125 mm
150 mm

3. Calculation example

A

Wall pipe, with louvred vent

= 1 x 3.8 m Additional duct
length

= 3.8 m

B/D

2 Elbows, 90°

= 2 x 0.8 m Additional duct
length

= 1.6 m

C

0.5 m plastic piping

= 0.5 x 1 m Additional duct
length

= 0.5 m

E

Side connection, left

= 1 m Additional duct length

= 1.0 m

Effective duct length

= 6.9 m

Result: A duct diameter of 100 mm is
adequate as the effective duct length is
less than the 20 m specified in Table II.

Installation to the rear, left or
right hand side of the machine

At the rear

The dryer is delivered with this connec-
tion open.

^ Fit one of the venting systems de-

scribed on the following pages.

Left or right side of the machine.

^ Remove the left or right hand side

cover cap. Do not remove the frame.
Refit it in the rear outlet.

^ Ensure it is securely in position so

that it cannot fall out when the dryer
is in operation.

^ Fit one of the venting systems de-

scribed on the following pages.