D main vent ing duct 35, D main venting duct, Installation - venting – Miele T 220 User Manual

Page 35: Main venting duct

Advertising
background image

Main venting duct

We recommend that when several dry-
ers are being installed each dryer
should be fitted with one non-return flap
installed directly on the main venting
duct (

R

, upper picture). Extra Miele

equipment is required for this purpose.

When up to five dryers are being in-
stalled, the pipe diameter

D

must be in-

creased according to Table III.

Table III

Number of Dryers

Magnification factor for

the pipe diameter from

Table II

2
3

4 - 5

1

1.25

1.5

1 Connection to the main venting duct
2 Miele non-return flap
3 Additional Miele adapter
4 Miele vent hose, very flexible

^ Push the non-return flap (2) com-

pletely into the adapter (3).

Installation - venting