Standard

Model Number

PD 30

PD 50

PD 75

PD 100

PD 125

PD 150

PD 175

PD 200

PD 250

PD 300

PD 350

PD 400

Btu/Hr. Input

30,000

50,000

75,000

100,000

125,000

150,000

175,000

200,000

250,000

300,000

350,000

400,000

Btu/Hr. Output

24,000

40,000

60,000

80,000

100,000

120,000

140,000

160,000

200,000

240,000

280,000

320,000

Entering Airflow CFM

440

740

1100

1460

1850

2180

2550

2870

3700

4460

4870

5440

Outlet Velocity

515

610

736

860

870

931

959

819

1053

1123

1068

1016

Air Temp. Rise °F

51

50

51

51

50

51

51

52

50

50

53

54

Mounting Hgt.

(Max. Ft.) ①

7

9

12

14

14

16

17

15

19

21

20

19

Heat Throw Ft. ①

(Max. Mtg. Hgt.)

25

33

41

49

51

55

59

51

67

74

70

69

Horsepower

1/40

1/40

1/12

1/12

1/8

1/8

1/6

1/6

1/3

1/2

3/4

3/4

RPM

1550

1550

1550

1550

1625

1625

1075

1075

1075

1075

1125

1125

Type

Shaded

Shaded

Shaded

Shaded

Perm.

Perm.

Perm.

Perm.

Perm.

Perm.

Perm.

Perm.

Pole

Pole

Pole

Pole

Split Cap. Split Cap.

Split Cap. Split Cap. Split Cap.

Split Cap. Split Cap. Split Cap.

Unit total

Power (amps)

1.3

1.3

2.5

2.5

2.6

2.6

3.1

3.1

5.7

7.8

8.3

8.3

DIMENSIONS/PERFORMANCE – PD

A

H

D (OPENING)

BB

E

AA

B

K

W

X

F

C

K

G

L - Approx

MIN. DISTANCE

TO WALL IS L + 6"

J VENT PIPE

EE

(MIN. DISTANCE TO WALL)

L

LL

Dimensions (inches) — PD

Do not use propeller units with duct work.

Performance — PD

Inputs and outputs are the same for BD as PD

Dimension

Model Number

Symbol

PD 30

PD 50

PD 75

PD 100

PD 125

PD 150

PD 175

PD 200

PD 250

PD 300

PD 350

PD 400

A

12-7/8

17-1/4

17-1/4

19-1/4

19-1/4

21

23-1/2

25-5/8

25-5/8

28-5/8

33-5/8

40

B

24-1/4

24-1/4

28-3/4

28-3/4

35-1/4

35-1/4

35-1/4

40-1/4

40-1/4

40-1/4

40-1/4

40-1/4

C

14-3/4

14-3/4

20

20

22

22

22

25

25

25

25

25

D

10-7/16

14-13/16

14-13/16 16-13/16

16-13/16

18-9/16

21-1/16

23-3/16

23-3/16

26-3/16

31-3/16

37-1/2

E

13

13

16

16

20

20

20

24

24

24

24

24

F

9-1/4

9-1/4

11

11

12

12

12

13-1/2

13-1/2

14

G

2

2

2-3/4

2-3/4

3-5/8

3-5/8

3-5/8

4-3/8

4-3/8

4-3/8

4-1/4

4-1/4

H

9-1/4

13-5/8

13-5/8

15-5/8

15-5/8

17-3/8

19-7/8

22

22

25

30

36-3/8

AA

5

5

6-1/4

6-1/4

8

8

8

9

9

9

9

9

BB

6-1/4

6-1/4

6-1/2

6-1/2

7-1/4

7-1/4

7-1/4

7-1/4

7-1/4

7-1/4

7-1/4

7-1/4

J ①

3

4

5

6

6

7

7

7

8

9

10

10

K (Mounting

3/8-16

3/8-16

3/8-16

3/8-16

3/8-16

3/8-16

3/8-16

3/8-16

3/8-16

3/8-16

3/8-16

3/8-16

Holes) ➂

Gas Connections ➁

1/2

1/2

1/2

1/2

1/2

1/2

1/2

1/2

1/2

1/2

3/4

3/4

W

5

5

X

16

16

L ➃

28-1/4

28-1/4

36

36

36-1/2

37-1/8

37-1/8

40-7/8

41

42-1/4

42-1/4

47-1/4

LL

19-1/2

20-1/8

30

30

30

31-1/8

31-1/8

34-7/8

34-7/8

36-1/4

35-1/2

40-1/2

EE

22-1/4

22-1/4

29

29

30-1/2

30-1/2

30-1/2

32-7/8

32-7/8

32-7/8

32-7/8

32-7/8

Fan Diameter

9

12

12

14

14

16

18

20

20

22

22

24

Approx. Weight

58#

72#

102#

116#

152#

162#

169#

231#

231#

261#

330#

410#

Ratings shown are for elevations up to 2,000 ft. For elevations above 2,000 feet, ratings should be reduced at the rate of 4% for each 1,000 feet above sea level. (In Canada see rating plate.)

At 65°F ambient and unit fired at full-rated input. Mounting height as measured from bottom of unit, and without deflector hoods.

All single phase motors are totally enclosed and thermal overload protected. Data listed is for standard 115-volt, 60 hertz, single-phase motors.

Diameter of round vent pipe to fit oval opening.

For natural gas; may vary depending on control availability.

PD 30 through PD 300 — 2 holes (and the level hanging adjustment feature). PD 350 through PD 400 — 4 holes.

Dimension equals overall plus 6".

Motor

Data

For clearance to combustibles, see page 3.

Heater Parts from ACF Greenhouses

Advertising
This manual is related to the following products: