Wiring

All field installed wiring must be done in accordance with the
National Electrical Code ANSI/NFPA 70 – Latest Edition or
Canadian Electrical Code CSA C22.1 Part 1 or local codes.
Unit must be electrically grounded according to these codes.
See wiring diagram shipped with unit.

The power to these unit heaters should be protected with a
circuit breaker. Units for use with single-phase electric power,
should be provided with a manual motor starter, having
properly sized overload protection. Units for use with three-
phase electric power must be provided with a motor starter
having properly sized overload protection.

Location of thermostat should be determined by heating
requirements and be mounted on an inside wall about 5' above
floor level where it will not be affected by heat from the unit or
other sources, or drafts from frequently opened doors. See
instructions packed with thermostat.

Installation of Blower Models (BD UNITS)

Attachment of Field Installed Ductwork, Blower
(BD) Models Only

Burned-out heat exchanger as well as shorter equipment life
will result from not providing uniform air distribution.

When installing heater always follow good duct design practices

for even distribution of the air across the heat exchanger.
Recommended layouts are shown below. When installing
blower units with ductwork the following must be done.

1. Provide uniform air distribution over the heat

exchanger.

Use turning vanes where required. See figures below.

2. Provide removable access panels in the ductwork on the

downstream side of the unit heater. These openings should
be large enough to view smoke or reflect light inside the
casing to indicate leaks in the heat exchanger and to check
for hot spots on exchanger due to poor air distribution or
lack of sufficient air.

3. If ductwork is connected to the rear of the unit use Modine

blower enclosure kit or if using field designed enclosure
maintain dimensions of blower enclosure as shown on page 13.

INSTALLATION

CAUTION

Disconnect power supply before making wiring connections
to prevent electrical shock and equipment damage. ALL
UNITS MUST BE WIRED STRICTLY IN ACCORDANCE
WITH WIRING DIAGRAM FURNISHED WITH UNIT.

ANY WIRING DIFFERENT FROM WIRING DIAGRAM MAY
BE HAZARDOUS TO PERSONS AND PROPERTY.

Any damage to or failure of Modine units caused by incorrect
wiring of the units is not covered by MODINE’S STANDARD
WARRANTY (see Back Cover).

CAUTION

Proper air flow and distribution, across the heat exchanger
must be provided to prevent early failure of the blower unit
heater.

CAUTION

Do not attempt to attach ductwork of any kind to propeller PD
models.

CAUTION

Check for red heat exchanger tubes. If bottom of tubes
become red while blower unit is in operation, check for
proper air volume and air distribution. Adjust blower speed or
correct discharge duct design to correct problem.

1/2

3/4

1

1 1/4

1 1/2

2

3

4

6

8

15

76

218

440

750

1220

2480

6500

13880

38700

79000

30

73

152

285

590

890

1650

4700

9700

27370

55850

45

44

124

260

435

700

1475

3900

7900

23350

45600

60

50

105

190

400

610

1150

3250

6800

19330

39500

75

97

200

345

545

1120

3000

6000

17310

35300

90

88

160

320

490

930

2600

5400

15800

32250

105

80

168

285

450

920

2450

5100

14620

29850

120

158

270

420

860

2300

4800

13680

27920

150

120

242

380

710

2000

4100

12240

25000

180

128

225

350

720

1950

4000

11160

22800

210

205

320

660

1780

3700

10330

21100

240

190

300

620

1680

3490

9600

19740

270

178

285

580

1580

3250

9000

18610

300

170

270

545

1490

3000

8500

17660

450

140

226

450

1230

2500

7000

14420

600

119

192

380

1030

2130

6000

12480

Table 3
Gas Pipe Capacities

In Cu. Ft. per Hour with Pressure Drop pf 0.3 in. W.C. with Specific Gravity 0.60.

Diameter of Pipe - Inches

Length of

Pipe in Ft.