Performance data – hoods for blower models, Heater parts from acf greenhouses – Modine Manufacturing GAS-FIRED HEATERS BD User Manual
Page 17

BD 50
BD 75
BD 100
BD 125
BD 150
BD 175
BD 200
BD 250
BD 300
BD 350
BD 400
Models
S
S
S
S
S
S
S
S
S
S
S
8'
29
42
56
61
72
79
70
98
113
121
94
10'
26
38
50
55
65
70
63
88
101
108
84
12'
24
35
46
50
59
64
58
80
92
99
77
14'
22
32
43
46
55
60
53
74
85
91
71
16'
21
30
40
43
51
56
50
70
80
85
67
18'
19
28
38
41
48
53
47
66
75
81
63
20'
27
36
39
46
50
45
62
71
76
60
22'
26
34
37
44
48
42
59
68
73
57
24'
24
33
35
42
45
41
57
65
70
55
26'
31
34
40
44
39
55
63
67
52
28'
30
33
39
42
38
53
60
65
50
30'
29
32
37
41
36
51
58
62
49
32'
31
36
39
35
49
56
60
47
34'
35
38
34
48
55
59
46
36'
46
53
57
45
38'
45
52
55
43
40'
44
50
54
42
42'
43
49
53
41
BD 50
BD 75
BD 100
BD 125
BD 150
BD 175
BD 200
BD 250
BD 300
BD 350
BD 400
Models
X Y Z
X Y Z
X Y Z
X Y Z
X Y Z
X Y Z
X Y Z
X Y Z
X Y Z
X Y Z
X Y Z
8'
0 31 42
0 40 55
0 50 68
0 50 69
0 56 77
0 60 82
0 53 73
0 68 93 0 74 102 0 78 107 0 66 90
10'
0 28 39
0 38 52
0 48 66
0 49 67
0 55 76
0 59 81
0 52 71
0 67 91 0 74 101 0 77 106 0 65 88
12'
0 25 34
0 36 49
0 47 64
0 47 65
0 54 74
0 57 79
0 50 69
0 65 90
0 72 99
0 76 104 0 63 87
14'
0 19 27
0 33 45
0 44 61
0 45 62
0 52 71
0 56 76
0 48 67
0 64 88
0 71 97
0 75 102 0 62 85
16'
0 11 16
0 29 40
0 42 57
0 42 58
0 50 68
0 54 74
0 46 63
0 62 85
0 69 95
0 73 100 0 60 82
18'
0 22 31
0 38 53
0 39 53
0 47 64
0 51 70
0 43 59
0 60 82
0 68 93
0 72 98
0 58 79
20'
0 33 46
0 34 47
0 43 60
0 48 66
0 39 54
0 58 79
0 65 90
0 70 95
0 55 76
22'
0 26 36
0 27 38
0 39 54
0 44 61
0 34 47
0 55 75
0 63 86
0 67 92
0 52 72
24'
0 16 24
0 33 45
0 39 54
0 24 34
0 51 70
0 60 82
0 64 89
0 48 66
26'
0 46 64
0 56 78
0 61 84
0 43 60
28'
0 40 56
0 52 72
0 57 79
0 36 50
30'
0 30 43
0 46 65
0 53 73
0 22 31
BD 50
BD 75
BD 100
BD 125
BD 150
BD 175
BD 200
BD 250
BD 300
BD 350
BD 400
Models
X Y Z
X Y Z
X Y Z
X Y Z
X Y Z
X Y Z
X Y Z
X Y Z
X Y Z
X Y Z
X Y Z
8'
13 29 40 18 38 52 22 47 64 23 47 64 26 53 72 28 56 76 24 50 68 31 63 86 35 69 94 37 73 99 30 61 84
10'
12 28 38 16 37 50 21 46 63 21 46 63 25 52 71 26 55 75 23 49 67 30 62 85 34 69 94 36 72 98 29 61 83
12'
10 25 35 15 35 48 20 45 61 20 45 62 23 51 70 25 54 74 22 48 66 29 62 84 33 68 93 34 71 97 28 60 82
14'
8 21 30 14 33 46 19 43 59 19 43 60 22 50 68 24 53 73 21 47 64 28 61 83 31 67 92 33 71 96 27 59 80
16'
12 30 42 17 41 57 17 42 57 21 48 66 23 52 71 19 45 62 27 59 81 30 66 90 32 69 95 26 57 79
18'
9 25 36 16 39 54 16 39 54 19 46 64 21 50 69 18 43 59 25 58 80 29 65 89 31 68 93 24 56 77
20'
14 35 50 14 36 50 18 44 61 20 48 66 16 40 56 24 56 77 28 63 87 30 67 92 23 54 75
22'
11 30 43 11 31 44 16 41 57 18 45 63 14 36 51 22 54 75 26 62 85 28 65 90 21 52 72
24'
13 36 51 16 42 59 10 29 42 21 52 72 25 59 82 27 63 87 20 49 69
26'
19 48 68 23 57 79 25 61 85 18 46 64
28'
16 44 62 21 54 75 23 58 81 15 41 58
30'
12 36 52 19 50 70 21 55 77 10 32 47
Mounting
Height to
Bottom of
Heater
Mounting
Height to
Bottom of
Heater
Mounting
Height to
Bottom of
Heater
17
PERFORMANCE DATA – HOODS FOR BLOWER MODELS
90° HOOD
60° Downward Hood For Blower Units ➁
90° Downward Hood For Blower Units ➁
➁
Data Based on unit fired at full rated input, 60°-80°F entering air temperature, and a 40°F temperature rise through
unit. Maximum mounting heights higher versus units without outlet devises.
Performance Data — 30°, 60° and 90° Downward Deflector Hoods
30° Downward Hood For Blower Units ➁
H
S
S