Chapter 5 - Error Correction, Data Compression, and Speed Conversion

5.10 Compression, Error Correction, Flow Control,

and Pacing Commands

The MT2834MR6 has several commands that control error correction, data compression, and flow control:

5.10.1 V.42 Error Correction Modes

&E0

Non-auto correction mode (no error correction).

&E1

Autoreliable mode (factory default).

&E2

Reliable mode.

5.10.2 Modem-Initiated Flow Control

&E3

Disable flow control.

&E4

CTS/RTS hardware flow control (factory default).

&E5

XON/XOFF software flow control.

5.10.3 XON/XOFF Pass-Through

&E6

Respond to and discard XON/XOFF characters when &E5 is selected (factory
default).

&E7

Respond to and pass through XON/XOFF characters when &E5 is selected.

5.10.4 Hewlett Packard ENQ/ACK Pacing

&E8

Ignore ENQ/ACK pacing characters (factory default).

&E9

Respond to ENQ/ACK pacing characters.

5.10.5 Non-Error Correction Mode Flow Control

&E10

Non-error correction mode flow control off (factory default).

&E11

Non-error correction mode flow control on.

5.10.6 Pacing (Computer-Initiated Flow Control)

&E12

Pacing off.

&E13

Pacing on (factory default).

5.10.7 Data Compression

&E14

Data Compression disabled.

&E15

Data Compression enabled.*

* The factory default setting for data compression is enabled, but the modem will not compress data unless

&E1

(autoreliable mode) or

&E2

(reliable mode) is also selected.