Appendix e, Appendix – Multi-Tech Systems MT2834MR6 User Manual

Page 97

Advertising
background image

97

Appendix

S34

1 char- 0–60

10

Sets the number of command characters allowed after +++AT.

acter

S36

1 sec

0, 1-255

5

Sets the time between DTR inactive and modem off-hook.
S36=0 disables DTR busy-out.

S37

1 sec

0-255

5

Sets the time between DTR active and modem on-hook.

S43

decimal 33, 31,

0

Sets fixed V.34 connect speed.

28, 26,

28 = 28800 bps; 26 = 26400 bps;. . .

24, 21,

48 = 4800 bps. 0 default disables this feature.

19, 16,

14, 12,

96, or 48

S48

decimal 33, 31,

0

Sets maximum V.34 connect speed.

28, 26,

33 = 33600 bps; 31 = 31200 bps;. . .

24, 21,

48 = 4800 bps. 0 default disables feature (same as S48=33).

19, 16,

14, 12,

96, or 48

S94

1 sec

0–254,

45

Sets the maximum time the modem remains out of service when

255

*H1

is active. S94=255 causes the modem to remain out of

service indefinitely, until it receives an enable from the
management software.

Advertising