Miller Electric Legend AEAD-200-LE User Manual

Page 24

Advertising
background image

TM-428 Page 20

Miller Legend

6-3.

Troubleshooting Circuit Diagram For Welding Generator With Optional Remote Control

Test Equipment Needed:

Resistance Values

a)

Tolerance –

±

10% unless specified

b)

Condition – 70

°

F (21

°

C); cold

machine (no warm-up)

c)

Wiring Diagram – see Section 9

d)

Stop engine before checking
resistance

R1

29 ohms

R2

34 ohms

R3

35 ohms

R4

2 ohms

R5

2 ohms

R6 thru R17

Less than 1 ohm

CR2 energized

Field current

at weld rpm

Throttle

control relay

control relay CR3

and auxiliary power

control relay CR4

energized at

power/idle rpm

V14/R17

V15

V16/

V17/

R1

R2

I1

I2

V11, V12,

V13/R12

V18

V19

R16

R15

R14

R13

Field flashing

disconnect relay CR5

See Section

6-11

for PC3 data

See Section 6-13

for PC5 data

See Section 6-5

for PC1 data

See Section

6-16 for R2 and

R4 adjustment

Advertising