Miller Legend

2-7.

Selecting Weld Cable Sizes

Total Cable (Copper) Length In Weld Circuit Not Exceeding

100 ft (30 m) Or Less

150 ft

(45 m)

200 ft

(60 m)

250 ft

(70 m)

300 ft

(90 m)

350 ft

(105 m)

400 ft

(120 m)

Welding

Amperes

10 – 60%

Duty Cycle

60 – 100%

Duty Cycle

10 – 100% Duty Cycle

100

4

4

4

3

2

1

1/0

1/0

150

3

3

2

1

1/0

2/0

3/0

3/0

200

3

2

1

1/0

2/0

3/0

4/0

4/0

250

2

1

1/0

2/0

3/0

4/0

2-2/0

2-2/0

300

1

1/0

2/0

3/0

4/0

2-2/0

2-3/0

2-3/0

350

1/0

2/0

3/0

4/0

2-2/0

2-3/0

2-3/0

2-4/0

Weld cable size (AWG) is based on either a 4 volts or less drop or a current density of at least 300 circular mils per ampere.

S-0007-D

2-8.

Remote 14 Receptacle RC1 Information

Socket*

Socket Information

A

Contact closure to B completes 15 volts dc contactor control
circuit.

B

15 volts dc.

C

+4.5 volts dc output to remote control.

A

J

B

K

I

A

D

Remote control circuit common.

B

C

L

N

H

D

M

G

E

F

A

E

0 to +4.5 volts dc input command signal from remote control.

ST-140 092-B

E

F

K

Chassis common.

*The remaining sockets are not used.