TM-428 Page 13

Miller Legend

13 Remote Control Switch S4

Selects Panel or remote amperage
control.

14 Circuit Breakers CB1, CB2,

CB5, And CB7

Protect 50/60 Hz auxiliary power
receptacles RC1, RC2, and RC3
from overload.

15 50/60 Hz Auxiliary Power Re-

ceptacles RC1, RC2, And
RC3

Provide connection points and
power for auxiliary equipment.

16 Circuit Breaker CB3

Protects 100 Hz auxiliary power re-
ceptacle RC4 from overload.

17 100 Hz Auxiliary Power Re-

ceptacle RC4

Provides connection point and
power for auxiliary equipment
while welding.

18 Fine Amperage Control R1

Adjusts amperage within range se-
lected by Ampere Ranges switch
S5.

19 Ampere Ranges Switch S5

Selects coarse range of weld out-
put from weld stator.

20 Reactor AC-Z

Tapped reactor limits weld output
and provides coarse ranges.

21 Main Rectifier SR1

Changes ac output from weld
windings to dc.

22 Stabilizer DC-Z

Smooths out current to dc weld
output terminals.

23 HF Filter Board PC4

Protects unit from high frequency.

24 Positive (+) And Negative (–)

DC Weld Output Terminals

Provide dc weld output.

25 Electrode And Work AC Weld

Output Terminals

Provide ac weld output.

Stabilizer

Main

Rectifier

SR1

Ampere
Ranges

Switch S5

Reactor

AC-Z

DC-Z

HF Filter

Board

PC4

Positive (+) And

Negative (–) DC

Weld Output

Terminals

Transformer

T1

Circuit

Breakers

CB1, CB2,

50/60 Hz

Auxiliary Power

Receptacles

RC1, RC2, RC3

19

20

21

22

11

14

15

23

25

24

Electrode And

Work AC Weld

Output Terminals

AC Or DC Control Circuits

Mechanical Coupling

Weld Current Circuit

Magnetic Coupling

Optional

CR4

CB5, CB7

Advertising