Miller Electric Legend AEAD-200-LE User Manual

Page 32

Advertising
background image

TM-428 Page 28

Miller Legend

6-11. Optional Remote Control Board PC3 Testing Information

Ref. ST-800 698-A / ST-115 941-L / SA-138 247

Be sure plugs are secure before
testing. See Section 6-12 for spe-
cific values during testing.

1

Remote Control Board PC3

2

Receptacle RC1

Test Equipment Needed:

1

2

6-12. Optional Remote Control Board PC3 Test Point Values

PC3 Voltage Readings

a) Tolerance –

±

10% unless

specified

b) Reference – to circuit com-

mon (lead 33) unless noted

Receptacle

Pin*

Value

RC1

1 (A)

Circuit common

2 (B)

Circuit common

3 (C)

+50 volts dc input at power/idle rpm; 100 volts dc input at weld rpm

4 (D)

+12 volts dc input with respect to pin 5 at power/idle or weld rpm

5 (E)

Chassis ground (lead 33)

6 (F)

59 to 6.8 volts dc output with respect to pin 1 from min to max of remote control with remote contac-
tor control switch closed, 130 volts dc output with remote contactor control switch open

7 (G)

Circuit common

8 (H)

Command reference output, +4.5 volts dc output with respect to pin 7

9 (J)

0 volts dc output with remote contactor control switch closed, +15 volts dc output with remote con-
tactor control switch open

10 (K)

0 to +4.5 volts dc input from min to max of Fine Amperage control R1 at power/idle rpm

*Letter(s) in parenthesis ( ) is pin letter prior to Serial No. KA840710.