TM-428 Page 25

Miller Legend

NO

Reinstall cover.

+12 volts dc present?

YES

Engine does not go to weld rpm with

Engine Control switch S2 in Run position.

NO

YES

+12 volts dc present?

Check connections

to Engine Control

switch S2 and

ground connection

(lead 33).

Start engine. Place Engine

Control switch S2 in Run position.

Check circuit breaker CB4, throttle

solenoid TS1 connections and

linkage, and control relay CR2.

Connect meter (DC) between

terminals D (+) and E (–).

Prior to Serial No. JH300534,

move Weld/Power switch S1 to

Weld position.

Control Relays CR3 and CR4 do not

energize at idle rpm (See Section 5 for

CR3 and CR4 information)

Reinstall cover.

NO

YES

+12 volts dc present?

Connect meter (DC) between

terminal A (+) and F (–) prior to

Serial No. JH300534, or B (+) and

F (–) effective with Serial No.

JH300534.

Start engine. Place Engine

Control switch in Run position.

NO

YES

0 (zero) volts dc present?

Check control relays

CR3 andCR4.

Place Engine Control switch S2

in Run/Idle position.

Replace idle

board/module

PC1

Replace idle

board/module

PC1

Replace idle

board/module

PC1

Connect meter (DC) between

terminals C (+) and E (–).