Section 3 − definitions, 1. symbol definitions, Section 4 − installation – Miller Electric Dimension 1000 User Manual

Page 15: 1. specifications

Advertising
background image

OM-2223 Page 11

SECTION 3 − DEFINITIONS

3-1. Symbol Definitions

A

Amperage

V

Voltage

Hz

Hertz

Direct Current

(DC)

Alternating Current

(AC)

Panel/Local

Line Connection

Three Phase

Output

On

Voltage Input

Off

Submerged Arc

Welding (SAW)

Read Operator’s

Manual

Remote

X

Duty Cycle

Percent

U

0

Rated No-Load

Voltage (Average)

U

1

Rated Supply

Voltage

Circuit Breaker

U

2

Conventional Load

Voltage

I

2

Rated Welding

Current

Protective Earth

(Ground)

I

1max

Rated Maximum

Supply Current

I

1eff

Maximum Effective

Supply Current

3-Phase Power

Source With

AC/DC Output

Temperature

Ventilating And Air

Circulating Fan

Increase

IP

Degree Of

Protection

Air Carbon Arc

Cutting (CAC-A)

Shielding Metal Arc

Welding (SMAW)

Gas Metal Arc

Welding GMAW)

SECTION 4 − INSTALLATION

4-1. Specifications

Model

Rated Welding

Output

Amperage/Voltage

Range DC

Max

OCV−DC

Amperes Input at Rated Load

Output,

60 Hz, Three-Phase

Output

Range DC

OCV DC

230 V

460 V

575 V

KVA

KW

1000 Amp

1000 A @ 44

Volts DC 100%

100 − 1250 A In CC

Mode

66 VDC**

180

5.8*

90

2.9*

72

2.4*

73

3.2*

53

0.5*

1000 Amp

Volts DC, 100%

Duty Cycle

10 − 60 V In CV

Mode

66 VDC**

5.8*

2.9*

2.4*

3.2*

0.5*

*While idling

**Open-circuit voltage is 26 volts dc if unit is equipped with optional low open-circuit voltage.