4-9. Selecting Cable Sizes

To reduce possible interference, keep weld cables as short as possible, close together, and down low, such as on the floor.

Locate welding operation 100 meters from any sensitive electronic equipment. Be sure this welding machine is installed

and grounded according to this manual. If interference still occurs, the user must take extra measures such as moving

the welding machine, using shielded cables, using line filters, or shielding the work area.

!

ARC WELDING can cause Electromagnetic Interference.

Total Cable (Copper) Length In Weld Circuit Not Exceeding

100 ft (30 m) Or Less

150 ft

(45 m)

200 ft

(60 m)

250 ft

(70 m)

300 ft

(90 m)

350 ft

(105 m)

400 ft

(120 m)

!

Do not use worn, dam-

aged, undersized, or

poorly spliced cables.

Welding

Amperes

10 − 60%

Duty

Cycle

60 − 100%

Duty Cycle

10 − 100% Duty Cycle

p

y p

100

4

4

4

3

2

1

1/0

1/0

150

3

3

2

1

1/0

2/0

3/0

3/0

200

3

2

1

1/0

2/0

3/0

4/0

4/0

250

2

1

1/0

2/0

3/0

4/0

2-2/0

2-2/0

300

1

1/0

2/0

3/0

4/0

2-2/0

2-3/0

2-3/0

350

1/0

2/0

3/0

4/0

2-2/0

2-3/0

2-3/0

2-4/0

400

1/0

2/0

3/0

4/0

2-2/0

2-3/0

2-4/0

2-4/0

500

2/0

3/0

4/0

2-2/0

2-3/0

2-4/0

3-3/0

3-3/0

600

3/0

4/0

2-2/0

2-3/0

2-4/0

3-3/0

3-4/0

3-4/0

700

4/0

2-2/0

2-3/0

2-4/0

3-3/0

3-4/0

3-4/0

4-4/0

800

4/0

2-2/0

2-3/0

2-4/0

3-4/0

3-4/0

4-4/0

4-4/0

900

2-2/0

2-3/0

2-4/0

3-3/0

3-4/0

4-4/0

4-4/0

1000

2-2/0

2-3/0

2-4/0

3-3/0

4-3/0

4-4/0

1250

2-3/0

2-4/0

3-3/0

4-3/0

4-4/0

*Weld cable size (AWG) is based on either a 4 volts or less drop or a current density of at least 300 circular mils per ampere. Contact your

distributor for the mm

2

equivalent weld cable sizes.

S-0007-E

4-10. Remote 14 Receptacle And Terminal Strip 1T Information

Socket

Terminal

Information

24 VOLTS AC

A

A

24 volts ac. Protected by circuit breaker CB2.

24 VOLTS AC

B

B

Contact closure to A completes 24 volts ac contactor control circuit.

C

C

Command reference; 0 to +10 volts dc (CC), +10 volts dc (CV).

REMOTE OUTPUT CONTROL

D

D

Remote control circuit common.

E

E

0 to +10 volts dc input command signal from remote control.

F

*

Current feedback; 0 to +10 volts dc, 1 volt per 100 amperes.

H

*

Voltage feedback; 0 to +10 volts dc, 1 volt per 10 arc volts.

115 VOLTS AC

I

I

115 volts, 15 amperes, 60 Hz ac. Protected by circuit breaker CB1.

115 VOLTS AC

J

J

Contact closure to I completes 115 volts ac contactor control circuit.

GND

K

G

K

*

Chassis common.
Circuit common for 24 and 115 volts ac circuits.

REMOTE POWER ON/OFF

*

L

To remote On/Off switch

REMOTE POWER ON/OFF

*

M

To remote On/Off switch.

REMOTE VOLTAGE SENSING

N

N

Voltage sensing signal from Negative (−) weld output terminal.

REMOTE VOLTAGE SENSING

*

P

Voltage sensing signal from Positive (+) weld output terminal.

* Not Used

Advertising