6. control box connections, 7. 14-pin plug information – Miller Electric SS-74S12 User Manual

Page 16

Advertising
background image

OM-1500−11 Page 12

Ref. 803 019

1

Interconnecting Cable

Receptacle

2

Interconnecting Cable

3

14-Pin Control Cable

4-6. Control Box Connections

1

2

3

4-7. 14-Pin Plug Information

Pin*

Pin Information

A

24 volts ac with respect to socket G.

B

Contact closure to A completes 24 volts ac contactor control circuit.

A

J

K

G

Circuit common for 24 volts ac circuit.

A

J

B

K

I

L

N

H

C

+10 volts dc output to remote control with respect to socket D.

C

L

N

H

D

M

G

D

Remote control circuit common.

D

M

G

E

F

E

0 to +10 volts dc input command signal from remote control with respect to socket D.

H

Voltage feedback; 0 to +10 volts dc, 1 volt per 10 arc volts.

F

Current feedback; 0 to +10 volts dc, 1 volt per 100 amperes.

*The remaining pins are not used.