12. setting internal dip switches – Miller Electric SS-74S12 User Manual

Page 19

Advertising
background image

OM-1500−11 Page 15

4-12. Setting Internal DIP Switches

Position Settings And Results For DIP Switch S1 On PC1 And PC101

On = Current detect over-

ride. For welding power

sources that don’t provide

current feedback through

the 14-pin receptacle. Run-

in is inactive.

Off = Current must be detected

from power sources that provide

current feedback through the

14-pin receptacle to go from run-in

to welding condition. Run-in wire

speed is active.

Remove wrapper.
1

DIP Switch S1 On Motor

Board PC1

w Setting Current Detect

Override (S1-1)

Current detect override is used to

disable run-in when a welding pow-

er source is used that doesn’t pro-

vide current feedback through the

14-pin receptacle.

.

Pins F & H are not present in 14

pin receptacle on machines

that don’t provide current feed-

back.

Install wrapper when finished.

1

803 063 / Ref. 802 944

.

In the DIP switch S1 illustrations,
the elevated slider on each switch

is shown in white. For example,

the switches above are all in the

Off position.

.

When DIP switch positions are changed, the unit must be
turned Off and then On again in order for the new settings

to be active. DIP switches are only read on power up.

Tools Needed:

1/4 in

This illustration shows

the factory setting of S1.

S1-1 And S1-2

S1-1 And S1-2

Current Detect Override (ON)

Current Detect Override (OFF)

P1

(Factory Default)

On = Run-In speed is

approximately 1/2 weld wire

feed speed.

Off = Run-In speed is set using

potentiometer P1 located on Motor

Board PC1.

S1-1 And S1-2

S1-1 And S1-2

Automatic Run-In (ON)

(Factory Default)

Automatic Run-In (OFF)