IBM 46xx

1. Turn off the host system.

2. Connect the keyed cable to the 10-pin

Multi-Interface jack. It is the only
circular keyed jack located on the
bottom of the MS7820

(see figure 8).


3. Connect the other end of the cable to

the host.

Before continuing, verify the cable is
connected to the proper communication
jack on the scanner. Incorrect cable
connection can cause communication
problems or potential damage to the
scanner.

4. Turn on the host system.

5. Scan

the

Recall Defaults bar code

to configure the MS7820 for
RS232/IBM communication.


6. Snap on the cable cover

For additional communication
options for IBM interfaces refer to the
MetroSelect Configuration Guide
(

MLPN

00-02407).

See SELV Power caution statement located on page 11 of this manual.

Plugging the scanner into the
serial port of the PC does not
guarantee that scanned
information will appear at the
PC. A software driver and
correct configuration setting
are also required for proper
communication to occur.