10. Reposition the camber inserts to the highest degree of camber. Refer to Adjusting Rear 

Wheel Camber on page 41.

11. Repeat STEP 3.

12. Close the left camber clamp. Refer to Opening/Closing Camber Clamps on page 39.

13. Rotate the right toe adjustment ring until the tab stops against the upper metal tab on 

the camber clamp.

14. Securely tighten set screw on right toe adjustment ring.

15. Repeat STEP 7.

16. Perform one of the following:

• Toe In/Toe Out Measurement is Within ±1/8‐inch ‐ 

i. Proceed to STEP 17.

• Toe In/Toe Out Measurement is Not Within ±1/8‐inch ‐ 

i. Repeat STEP 1.

ii. Loosen the set screw on the right toe adjustment ring.

iii. Repeat STEP 3.

iv. Repeat STEPS 12‐16 until toe in/toe out measurement is within ±1/8 inch.

17. If desired, reposition camber inserts to the desired degree of camber. Refer to 

Adjusting Rear Wheel Camber on page 41.

FIGURE 5.17 Adjusting the Axle Tube - A4 Camber System

Camber

Clamp

Higher Degree of Camber

Axle Tube - Will Rotate Down only

Ground/Floor

90° Angle

Place “L” Square Here

Flat Edge of

Camber Tube

Lower Degree of Camber

Right Tab

Stopped

Against

Upper Edge

of Camber

Clamp

Right Toe Adjustment

Ring

Left Tab
Stopped

Against

Lower Edge

of Camber

Clamp

Left Toe

Adjustment

Ring

Camber

Clamp

Axle Tube - Will

Rotate Up only