Pll adjustment, Frequency adjustment, 2 pll adjustments – Icom IC-910H User Manual

Page 20: 3 frequency adjustment

Advertising
background image

5 - 2

5-2 PLL ADJUSTMENTS

30.2 MHz
LEVEL

REFERENCE
FREQUENCY

144M LOCK
VOLTAGE

440M LOCK
VOLTAGE

MAIN BFO
LEVEL

SUB BFO
LEVEL

ADJUSTMENT

ADJUSTMENT

ADJUSTMENT CONDITION

MEASUREMENT

VALUE

POINT

UNIT

LOCATION

UNIT

ADJUST

1

1

2

1

2

3

1

2

3

1

2

• Display frequency: Any
• Receiving

• Display frequency: Any
• Receiving

This adjustment must be performed
at 5 minutes later after power ON.

• Display frequency: 173.9800 MHz
• Mode

: USB

• Receiving

• Display frequency: 136.0200 MHz
• Receiving

• Display frequency: 155.0000 MHz
• Receiving

• Display frequency: 479.9800 MHz
• Mode

: USB

• Receiving

• Display frequency: 420.0200 MHz
• Receiving

• Display frequency: 450.0000 MHz
• Receiving

• Display frequency: Any
• Mode

:USB

• Receiving

• Sub display freq. : Any
• Mode

:USB

• Receiving

PLL

PLL

PLL

PLL

PLL

PLL

Connect an RF volt-
meter or spectram
analyzer to check
point J541.

Connect an RF volt-
meter or spectram
analyzer to check
point P551.

Connect a frequency
counter to check
point P551.

Connect a digital
multimeter or oscillo-
scope to check point
CP100.

Connect an RF volt-
meter to check point
P251.

Connect a digital
multimeter or oscillo-
scope to check point
CP300.

Connect an RF volt-
meter to check point
P421.

Connect an RF volt-
meter to check point
P601.

Connect an RF volt-
meter to check point
P701.

–10 dBm (or more than
–11.5 dBm, when R570
is in maximum posi-
tion.)

Maximum level

(–13 dBm to –7dBm)

60.400000 MHz

2.7 V

0.6 V to 1.6 V

–10 dBm to –4 dBm

3.4 V

0.5 V to 1.5 V

–16 dBm to –10 dBm

–11 dBm to –5 dBm

–11 dBm to –5 dBm

PLL

PLL

PLL

PLL

PLL

PLL

R570

Adjust in
sequence
L551, L552
s e v e r a l
times.

The trimmer
capacitor of
X512.

L193

Verify

Verify

C402

Verify

Verify

Verify

Verify

5-3 FREQUENCY ADJUSTMENT

FM TX-LO
FREQUENCY

ADJUSTMENT

ADJUSTMENT

ADJUSTMENT CONDITION

MEASUREMENT

VALUE

POINT

UNIT

LOCATION

UNIT

ADJUST

1 • Display frequency: Any

• Mode

: FM

• Disconnect P501, P502 (PA unit)

from J51 and J52 on the MAIN unit.

• Apply no audio signals to [MIC]

connector.

• Transmitting

MAIN

Connect a frequency
counter to check
point CP51.

10.85000 MHz

MAIN

L255

After adjustment, connect P501, P502 (PA unit) to J51, J52 on the MAIN.

Advertising