Software adjustment (continued) – Icom IC-910H User Manual

Page 31

Advertising
background image

*This output level of a standard signal generator (SSG) is indicated as SSG’s open circuit.

5 - 13

SOFTWARE ADJUSTMENT (continued)

ADJUSTMENT
ITEM (2)
S-METER
(MAIN BAND)

(SUB BAND)

ADJUSTMENT

ADJUSTMENT CONDITION

DISPLAY

OPERATION

• Enter software adjustment mode (Refer

page 5-12).

• Push [2] key to enter the S-meter adjust-

ment

• Connect an SSG to [VHF ANT] connector

and set as

:

Frequency

: 146.0200 MHz

Level

: OFF

• Receiving

• Set an SSG as

:

Frequency

: 146.0200 MHz

Level

: 3.2 µV* (–97 dBm)

• Receiving

• Set an SSG as

:

Frequency

: 146.0200 MHz

Level

: 1 mV* (–47 dBm)

• Receiving

• Set an SSG as

:

Frequency

: 146.0200 MHz

Level

: OFF

• Receiving

• Set an SSG as

:

Frequency

: 146.0200 MHz

Level

: 3.2 µV* (–97 dBm)

Modulation

: OFF

• Receiving

• Set an SSG as

:

Frequency

: 146.0200 MHz

Level

: 32 µV* (–77 dBm)

• Receiving

• Set an SSG as

:

Frequency

: 146.0200 MHz

Level

: OFF

• Receiving

• Set an SSG as

:

Frequency

: 146.0200 MHz

Level

: 3.2 µV* (–97 dBm)

• Receiving

• Set an SSG as

:

Frequency

: 146.0200 MHz

Level

: 1 mV* (–47 dBm)

• Receiving

1

2

3

4

5

6

7

8

9

Push [RIT] key to store the “S0” level
into memory, and to step next.

Push [RIT] key to store the “S9” level
into memor, and to step next.

Push [RIT] key to store the “S9+60”
level into memory, and to step next.

Push [RIT] key to store the “S0” level
into memory, and to step next.

Push [RIT] key to store the “S9” level
into memory, and to step next.

Push [RIT] key to store the “S9+60”
level into memory, and to step next.

Push [RIT] key to store the “S0” level
into memory, and to step next.

Push [RIT] key to store the “S9” level
into memory, and to step next.

Push [RIT] key to store the “S9+60”
level into memory, and to step next.

USB

USB

USB

USB

USB

SUB

USB

SUB

USB

SUB

FM

FM

FM

USB

USB

Advertising