*This output level of a standard signal generator (SSG) is indicated as SSG’s open circuit.

5 - 18

5-7 UX-910 ADJUSTMENTS

2ND LO LOCK
VOLTAGE

1ST LO LOCK
VOLTAGE

RECEIVER
GAIN

ATT GAIN

IDLING

POWER
BALLANCE

TRANSMITTER
GAIN

ADJUSTMENT

ADJUSTMENT

ADJUSTMENT CONDITION

MEASUREMENT

VALUE

POINT

UNIT

LOCATION

UNIT

ADJUST

1

1

2

1

1

1

1

2

3

4

1

• Connect an optional UX-910 (1200

MHz band unit).

• Display frequency: 1270.5000 MHz
• Receiving

• Display frequency: 1240.0000 MHz
• Receiving

• Display frequency: 1300.0000 MHz
• Receiving

• Display frequency: 1280.0000 MHz
• Connect a standard signal generator

to [12 ANT] connector and set as:

Frequency : 1280.0000 MHz
Level

: 710 µV* (–50 dBm)

Modulation : OFF

• Receiving

• Display frequency: 1280.0000 MHz
• [ATT]

: ON

• Set an SSG as

:

Frequency : 1280.0000 MHz
Level

: 710 µV* (–50 dBm)

Modulation : OFF

• Receiving

• Display frequency: Any
• Mode

: CW

• Preset R61, R67, R83 to max.

clockwise, R13 to max. counter
clockwise, and C332 to center.

• Connect an RF power meter to [12

ANT].

• Connect an SSG to the check point

CP311 and set as :

Frequency : 10.8500 MHz
Level

: OFF

• Transmitting

• Display frequency: Any
• Mode

: CW

• Connect an SSG to the check point

CP311 and set as :

Frequency : 10.8500 MHz

• Transmitting

• Display frequency: 1240.0000 MHz
• Transmitting

• Display frequency: 1300.0000 MHz
• Transmitting

• Display frequency: 1270.0000 MHz
• Set an SSG as

:

Frequency : 10.8500 MHz
Level

: 18 mV* (–22 dBm)

• Transmitting

MAIN

(UX-910)

MAIN

(UX-910)

MAIN

(UX-910)

MAIN

(UX-910)

MAIN

(UX-910)

Rear

panel

Rear

panel

Connect a digital
multimeter or oscillo-
scope to check point
CP701.

Connect a digital
multimeter or oscillo-
scope to check point
CP501.

Connect a spectram
analyzer to check
point CP311.

Connect a spectram
analyzer to check
point CP311.

Connect a digital
multimeter between
check points CP321
and CP322.

Connect an RF
power meter to [12
ANT].

Connect an RF
power meter to [12
ANT].

2.6–3.8 V

6.0–7.0 V

3.4–4.4 V

–34 dBm (16 dB gain)

–14 dBm (20 dB of gain
difference between the
attenuator ON and
OFF.)

0.5 V

voltage difference

5 W

Read the RF power
meter indication.

Same power as step 2

5 W

MAIN

(UX-910)

MAIN

(UX-910)

MAIN

(UX-910)

MAIN

(UX-910)

MAIN

(UX-910)

Verify

Verify

R224

R288

R13

Adjust
SSG’s

level

Verify

C332

R83

Repeat step 2 and step 3 several times until power difference is minimum.