Ux-910 adjustments (continued) – Icom IC-910H User Manual

Page 38

Advertising
background image

*This output level of a standard signal generator (SSG) is indicated as SSG’s open circuit.

5 - 20

UX-910 ADJUSTMENTS (continued)

APC

(POWER SET)

ADJUSTMENT

ADJUSTMENT

ADJUSTMENT CONDITION

MEASUREMENT

VALUE

POINT

UNIT

LOCATION

UNIT

ADJUST

1

2

3

4

5

• Display frequency: 1270.0000 MHz
• Mode

: CW

• Connect an SSG to the check point

CP311 and set as :

Frequency : 10.8500 MHz

• Transmitting

• Transmitting

• Transmitting

• Transmitting

• Transmitting

Rear

panel

MAIN

(UX-910)

Rear

panel

MAIN

(UX-910)

Connect an RF
power meter to [12
ANT].

Connect a digital
multimeter or oscillo-
scope to check point
CP15.

Connect an RF
power meter to [12
ANT].

Connect a digital
multimeter or oscillo-
scope to check point
CP401.

Connect a digital
multimeter or oscillo-
scope to check point
CP15.

13 W

3.0 V

10.5 W

3.1 V

3.0 V

MAIN

(UX-910)

MAIN

(UX-910)

MAIN

(UX-910)

Adjust
SSG’s

level

R37

Adjust
SSG’s

level

R67

R61