Receiver adjustments (continued) – Icom IC-910H User Manual

Page 24

Advertising
background image

*This output level of a standard signal generator (SSG) is indicated as SSG’s open circuit.

RECEIVER ADJUSTMENTS (continued)

430 M PEAK
(MAIN BAND)

430 M PEAK
(SUB BAND)

430 M
TOTAL GAIN
(MAIN BAND)

NOISE
BLANKER
(MAIN BAND)

(SUB BAND)

1

1

1

2

1

2

3

4

• Display frequency: 435.0200 MHz
• Mode

: FM

• Connect a standard signal generator

to [UHF ANT] connector and set as:

Frequency : 435.0200 MHz
Level

: 1 µV* (–107 dBm)

Modulation : 1 kHz/±5.0 kHz Dev.

• Receiving

• Sub display freq. : 435.0200 MHz
• Mode

: FM

• Set an SSG as

:

Frequency : 435.0200 MHz
Level

: 1 µV* (–107 dBm)

Modulation : 1 kHz/±5.0 kHz Dev.

• Receiving

• Display frequency: 435.0200 MHz
• Mode

: USB

• Set an SSG as

:

Frequency : 435.0215 MHz
Level

: 1 mV* (–47 dBm)

Modulation : OFF

• Receiving

• Set an SSG as

:

Level

: OFF

• Receiving

• Display frequency: 145.9800 MHz
• Mode

: USB

• [NB]

: OFF

• Connect an SSG to [VHF ANT] con-

nector and set as :

Frequency : 145.98150 MHz
Level

: 5.6 µV* (–92 dBm)

Modulation : OFF

and apply following signal to [VHF
ANT] connector.

• Receiving

• [NB]

: ON

• Set an SSG as

:

Level

: 3.2 µV* (–97 dBm)

• Receiving

• Sub display freq. : 145.9800 MHz
• Mode

: USB

• [NB]

: OFF

• Set an SSG as

:

Level

: 5.6 µV* (–92 dBm)

• Receiving

• [NB]

: ON

• Set an SSG as

:

Level

: 3.2 µV* (–97 dBm)

• Receiving

MAIN

MAIN

Rear

panel

MAIN

100 msec.

1 msec.

5 - 6

ADJUSTMENT

ADJUSTMENT

ADJUSTMENT CONDITION

MEASUREMENT

VALUE

POINT

UNIT

LOCATION

UNIT

ADJUST

Connect a digital
multimeter or oscillo-
scope to check point
CP851.

Connect a digital
multimeter or oscillo-
scope to check point
CP852.

Connect an AC milli-
volt meter to [EXT
SP] connector with
an 8

Ω load.

Connect an oscillo-
scope to check point
CP101.

Connect an oscillo-
scope to check point
CP701.

Maximum voltage

Maximum voltage

1.0 V (0 dB)

100 mV (20 dB of AF
level difference as step
1.)

Maximum noise wave-
form

The noise must be
blanked.

Maximum noise wave-
form

The noise must be
blanked.

PA

PA

Front

panel

PA

MAIN

L22,
L23,

L282,
L283

L280,
L281

main [AF]

volume

R61

L102,
L103

Verify

L703,
L704

Verify

Advertising