OPERATION

21

5

D

D MONITOR AUDIBLE FUNCTION
The monitor function allows you to open the transceiver’s squelch
manually to check whether a channel is busy or not. The trans-
ceiver has 2 conditions for receive standby:

Audible condition:
This condition mutes audio ONLY when
no carrier is present. You can receive (or
monitor) any signals on a channel.
• Push and hold the [MONI], switch to se-

lect the audible condition.

Any audio mute functions are cancelled
while pushing the [MONI] switch.

Inaudible condition:

This condition mutes ALL signals except
those directed to you. Therefore you
should check a channel’s condition (busy
or not) with the monitor function before
transmitting.
• Push the [MONI] switch momentarily to
select the inaudible condition.

D

D TIME-OUT TIMER
After continuous transmission for a pre-programmed period, the
time-out timer is activated, causing the transceiver to stop transmit-
ting and automatically selects receive.

• The time-out timer function is automatically turned ON when 3

min. has passed.

D

D POWER SAVE FUNCTION
The power save function reduces the current drain to conserve bat-
tery power.

• The power save function is automatically turned ON when no

operation is performed or no signal is received for 5 sec.

All signals are
received

Only signals con-
taining the proper
tone are received