Flue outlet – IDEAL INDUSTRIES CLASSIC HE18 User Manual

Page 23

Advertising
background image

classic HE -

Installation & Servicing

23

INSTALLATION

FLUE OUTLET

31 FITTING THE OPTIONAL ROOF FLUE KIT (Flat or Pitched)

Note.
A flat or pitched roof flashing plate (not supplied) is
required before proceeding with the installation of this
kit.

This kit is suitable for both flat and pitched roof
terminations, using a concentric flue to run vertically
from the top of the boiler and terminating above roof
level.

Connection to the top of the boiler is made using a
separately supplied vertical connector kit.

WEATHER PROOFING

Where the flue passes through the roof line an
adequate seal must be made. This is achieved by
using either:
Flat roof weather collar or Universal weather collar.

ACCESSORIES

Flue Duct Extension Kits are available for flue lengths
extending beyond 1m. These packs contain 1m
extension ducts and may be cut to the desired length.

If the offset vertical option is used an elbow Kit is
required. For a full accessories list refer to page 6,
Optional Extras and Frame 34, Flue Arrangement.

32 ROOF FLUE KIT CONTENTS / OPTIONS

A. Flue assembly with terminal
B. Flue seal collar
C. 3,5x13 screw
D. Pitched roof tile/flat roof tile

weather collar

E. Vertical connector (60/100)/

boiler vertical conversion kit

F. Roof flue extension duct kit

(60/100)

G. 90

o

elbow kit (60/100)

H. 45

o

elbow kit (60/100)

Note. Items D, E, F, G and H are not supplied with the roof flue kit.

A

H

G

C

B

D

E

mxhe7681

F

ex7534

201850-6.pmd

21/02/2008, 12:58

23

Advertising
This manual is related to the following products: