IDEAL INDUSTRIES CLASSIC HE18 User Manual

Page 4

Advertising
background image

4

classic

HE

-

Installation & Servicing

GENERAL

CAUTION.

To avoid the possibility of injury during the installation, servicing or cleaning

of this appliance, care should be taken when handling edges of sheet steel components

Boiler Size

HE9

HE12

HE15

HE18

Gas supply connection

(in. BSP)

Rc 1/2 (1/2) 1/2" (BSP Female)

Flow connection

22mm

copper

Return connection

22mm

copper

Maximum static water head

m (ft.)

30.5 (100)

Minimum static water head

m (ft.)

0.45 (1.5)

Electrical supply

230 V 50 Hz Boiler power consumption; 100W

Fuse rating

External; 3A Internal; F1A to BS.4265

Water content

litre (gal.)

3.0 (0.67)

3.95 (0.87)

Packaged Weight

kg (lb)

45 (99)

50 (110)

Maximum installation weight

kg (lb)

40 (88)

45 (99)

Boiler size

Height mm (in.)

700 (27.5)

Width mm (in.)

380 (15.0)

Depth mm (in.)

280 (11.25)

Flue duct diameter

mm (in.)

100 (4.0)

Flue duct length (max)

m (ft)

3 (9.8)

Note. Gas consumption is calculated using a calorific value of
38.7 MJ/m

3

(1038 Btu/ft

3

) gross or 34.9 MJ/m

3

(935 Btu/ft

3

) nett

To obtain the gas consumption at a different calorific value:-

a. FOR L/S - divide the gross heat input (kW) by the gross C.V.

of the gas (MJ/m

3

)

b. FOR FT

3

/H - divide the gross heat input (Btu/h) by the gross

C.V. of the gas (Btu/ft

3

)

Table 1 - General Data

*

The value is used in the UK Government's Standard Assessment Procedure (SAP) for energy rating of
dwellings. The test data from which it has been calculated have been certified by a notified body.

Table 2 - Performance Data

Key to symbols
GB
= United Kingdom

IE = Ireland (Countries of destination)

PMS = Maximum operating pressure of water
C

12

C

32

= A room sealed appliance designed for connection via

ducts to a horizontal or vertical terminal which admits
fresh air to the burner and discharges the products of
combustion to the outside through orifices which, in
this case, are concentric. The fan is down stream of
the combustion chamber.

I

2H

=

An appliance designed for use on 2nd Family gas,
Group H only.

Boiler Size

HE9

HE12

HE15

HE18

Input 'Q'

Nett CV kW (Btu/h)

9.4 (32,100)

12.6 (43,000)

15.7 (53,600)

18.9 (64,500)

Gross CV kW (Btu/h)

10.5 (35,800)

14.0 (47,800)

17.4 (59,400)

20.9 (71,300)

Gas Consumption l/s (cu.ft/h)

0.27 (34.3)

0.36 (45.8)

0.45 (57.2)

0.54 (68.7)

Output 'P

70

o

C Mean Water temp. kW (Btu/h)

9.0 (30,700)

12.0 (40,900)

15.0 (51,200)

18.0 (61,400)

40

o

C Mean Water temp. kW (Btu/h)

9.8 (33,400)

13.1 (44,700)

16.2 (55,300)

19.4 (66,200)

Burner Setting Pressure (Hot)

mbar (in w.g.)

12.0 (4.8)

10.4 (4.2)

12.3 (4.9)

12.7 (5.1)

Seasonal efficiency (SEDBUK) *

Band B

[87.2]%

[87.2]%

[86.8]%

[86.8]%

NOx classification

Class 3

Class 2

Class 1

Class 1