77 SIPHON REPLACEMENT

1. Refer to Frame 61.
2. Remove the burner. Refer to

Frame 54.

3. Pull the heat shield forward to

remove from clips.

4. Pull off the rubber sump connecting

pipe and the blockage sensing pipe.

5. Unscrew the siphon union

connection.

6. Remove the two siphon retaining

screws and remove siphon.

7. Re-fit the new siphon and gasket

and reassemble in reverse order,
ensuring the rubber sump
connecting pipe and blockage
sensing pipe are correctly
replaced.

8. Ensure the siphon is charged with

water and the heat shield is
replaced.