Chapter 2 — Configuring the PB50

36

PB50 Mobile Label and Receipt Printer User’s Guide

where xxxxxxxxxx can be a value from 0 to 64 characters.

Send the following command to make sure your values match
those used by the access point:

setup write "8021x","uart1:"

You may need to send the following command several times for
the wireless station to connect:

setup "wlan","ACTIVE","1"<ETX>

Setting Up USB Communications

To set up USB communications with your PC, you will need:

USB cable

Intermec InterDriver® software

You can download the InterDriver software from the Intermec web
site at

www.intermec.com

.

Setting Up Serial Communications

Use a serial cable (P/N 075497-001) to connect the PB50 to a PC or a
mobile computer. For the mobile computer, you may need to
purchase a serial adapter. For more information, contact your local
Intermec sales representative.

Before you can establish a serial connection, you need to make sure
that the settings on the PC or mobile computer match those of the
PB50.

Serial Port Settings on the PB50

Parameter

Default Setting

Baud rate

115200

Data bits

8

Parity

None

Stop bits

1

Flow control

XON_XOFF (IPL)

RTS/CTS (ESC/P)

Advertising