Introduction 1 – I-O Display Systems Basic I/O Product User Manual

Page 50

Advertising
background image

Introduction 1

1-4(Vol.2)

Available I/O functionality:

Analog Input Functions

Input value

Determines signal levels, with 12 bits resolution

1

Offsets

Input values can be software offset, with 12

bits resolution,

over the module’s specified range.

Gain/ Slope

The amplitude of input values can be software multiplied by
factors ranging from 0.25 to 4.0.

Range Limits

The occurrence of input values falling out of user defined upper
or lower limits can be flagged.

Minimums

The minimum level of input values can be captured.

Maximums

The maximum level of input values can be captured.

Averages

Can calculate average input amplitude for 1-65,535 samples.

Temperature

Can linearize in, °C, inputs from thermocouples and RTDs.
Will also return temperature probe data.

Analog outputs

Level Value

Can set output levels, as a function of the module’s full scale
range, and are specified with 12 bits resolution.

Waveforms

can provide square, triangular, sawtooth, or ramp waveforms.
Maximum and minimum amplitudes, as a fraction of the output
module’s full scale range, are specified with 12 bits
resolution. Waveform periods are specified 0.1 to 6,553 Sec
(109 Min). All waveforms are made up of at least ten
segments.

1

One part in 4095

Advertising