5-3 UT-115 ADJUSTMENT PROCEDURES

• PREPARATION

Enter the adjustment mode when adjusting the UT-115.

REQUIRED TEST EQUIPMENT

DC power supply 1

DC power supply 2

Frequency counter

Oscilloscope

EQUIPMENT

GREDE AND RANGE

EQUIPMENT

GREDE AND RENGE

Output voltage

: 5.0 V DC

Current capacity

: 1 A or more

Output voltage

: 8.0 V DC

Current capacity

: 1 A or more

Frequency range

: 0.1–100 MHz

Frequency accuracy

: ±1 ppm or better

Sensitivity

: 100 mV or better

Frequency range

: DC–400 MHz

Measuring range

: 0.01–10 V

ENTERING THE ADJUSTMENT MODE

Connect J301, pin 14 to GND, then the UT-115 enters adjustment mode.

NOTE:

Exit from the adjustment mode to disconnect J310, pin 14 from GND before the UT-115 adjustment is fihished

CONNECTION

Power supply

8 V DC / 1 A

Power supply

5 V DC / 1 A

J301, Pin 14
Entering adjustment mode

• UT-115 BOTTOM VIEW