Ut-115 trimmer adjustments, 4 trimmer adjustments – Icom IC-2200H User Manual

Page 22

Advertising
background image

5 - 6

5-4 TRIMMER ADJUSTMENTS

CODEC
FREQUENCY
SET

MODEM
FREQUENCY
SET

MODURATION
OUTPUT
LEVEL

ADJUSTMENT

ADJUSTMENT

MEASUREMENT

MEASUREMENT

VALUE

POINT

UNIT

LOCATION

UNIT

ADJUST

1

1

1

2

3

MAIN

MAIN

MAIN

Connect the frequency counter to
the check point CP101.

Connect the frequency counter to
the check point CP216.

• Transmit the UT-115 to connect

J301, pin 1 to GND.

• Connect the oscilloscope to the

J301, pin 21.

Disconnect J301, pin 1 from GND.

16.38400 MHz ±10 Hz

2.457600 MHz ±3 Hz

350 mV

p-p

±10 mV

MAIN

MAIN

MAIN

C102

C207

R264

J301, Pin 21
Modulation output level
check point

J301, Pin 1
Transmit the UT-115

CP101
CODEC frequency set check point

CP216
MODEM frequency set check point

C207
MODEM frequency set adjustment

C102
CODEC frequency set adjustment

• UT-115 TOP VIEW

• UT-115 BOTTOM VIEW