45

19x

The computer chassis-intrusion
detector was cleared. This is an
informational message.

No action is required.

2xx

Memory error

Go to “Running the IBM Enhanced
Diagnostics program” on page 57 for
instructions on running memory
diagnostics.

301 or
303

Keyboard error

1. Make sure the keyboard is

properly connected.

2. If the keyboard is properly

connected, have the computer
serviced.

604

Unsupported diskette drive
installed

1. Go to “Running the IBM Enhanced

Diagnostics program” on page 57
and follow the instructions for
running the IBM Enhanced
Diagnostics program.

2. If the problem persists, have the

computer serviced.

605

Diskette unlocked problem

Have the computer serviced.

662

Diskette drive configuration error

1. Go to “Starting and using the

Configuration/Setup Utility
program” on page 27, and follow
the instructions to verify the
diskette drive configuration.

2. Run the diagnostic program for

the diskette drive. See “Running
the IBM Enhanced Diagnostics
program” on page 57.

3. If the problem persists, have the

computer serviced.

762

Math coprocessor configuration
error

Have the computer serviced.

1762

Hard disk configuration error

1. Go to “Starting and using the

Configuration/Setup Utility
program” on page 27, and follow
the instructions to verify the hard
disk configuration.

2. If the problem persists, have the

computer serviced.

Code